Titration Test Kit PA-15

Product Code

0007500-KIT-001

Product Description

Use this kit to determine the concentration of Seacole detergent in a cleaning solution.

  1. Take a sample of the cleaning solution, filling the graduated test tube with the amount from the chart below (either 12.5 mL, 25 mL, or 50 mL).
  2. Add approximately 5 drops of Phenolphthalein Indicator until pink color is evident.
  3. Hold the Phosphoric Acid 15% bottle vertically and add one drop at a time to the sample, stir regularly, and count the number of drops added until pink color disappears.
  4. Rinse the graduated test tube and repeat as needed to ensure a precise count.
  5. Divide the number of Phosphoric Acid 15% drops by ‘X’ from the chart below to approximate the percent concentration of Seacole detergent in the cleaning solution.

Performance Features


12.5 mL Solution:

Sonic Blast X= 0.50

Spraydet RS X= 9.40

Spraydet S X= 8.70

Spraydet EP X= 5.63


25 mL Solution:

Spraydet 14EX X= 9.40

Spraydet EL X= 2.20

Spraydet EV X= 0.50

Spraydet HG X= 3.17


50 mL Solution:

Aqua Force X=0.36

Aqua UL X=0.66

Spraydet CW X=1.38

Spraydet EC X=0.91

CONTACT US

More Products

Boat Hull Cleaner (Powder)

Boat Hull Cleaner (Powder) is an acid based, powdered detergent formulated for fiberglass and painted wood boat hulls.

Spraydet RS

Spraydet RS is a highly alkaline powdered detergent engineered to produce superior cleaning results for the removal of the toughest contaminates on all ferrous metal surfaces.

C&H 810S Stick

C&H 810S is a multi-metal safe corrosion inhibitor for use in diesel engine cooling systems to protect from premature failure due to corrosion.
Seacole Logo Horiz Rgb 400px.png

Contact Us